Bug #5133
openIncorrect work of USALS
0%
Description
There is a TBS5580 and a Moteck SG-2500 motor. Periodically, the motor can start moving only after I start the channel several times in a row. After a long downtime (more than 8-10 hours) the same problems.
Files
Updated by Jaroslav Kysela almost 7 years ago
--trace linuxdvb,diseqc : https://tvheadend.org/projects/tvheadend/wiki/Traces
Describe the log (assign time to the action or what action do you expect).
Also, describe your equipment (topology). I would prefer this than to pick the info from the config images.
Updated by Vlad Lanetz almost 7 years ago
- File tvheadend.log tvheadend.log added
TBS5580 -> Diseqc 1.0 4 port -> Motor
First I started the channel with a 53E but the motor on it not turned, after launched channels 60E and there he began to move.
Updated by Jaroslav Kysela almost 7 years ago
Try to increase DiseqC repeats for the rotor config. If you look to the log, the tvh correctly sends the USALS diseqc commands and waits for the rotor move.
Updated by Vlad Lanetz almost 7 years ago
I tried pointing out 1 and 2 but it didn't help.
Updated by Digi Hoe almost 7 years ago
Do you have the problem if you use port1 for the motor on your switch?
Best regards!