Bug #5517
SATIP Client: Rolloff is mandatory for some devices
0%
Description
For some SAT>IP servers that I have tried such as Kathrein EXIP 4124 or Triax TSS400, I have noticed that if you try to scan a DVB-S2 mux without the Rolloff set with some defined value the server does not send any data.
Is there any possibility of activating an option (perhaps a specific firmware solution for these devices) so when a rolloff is not established, for example, 35 is sent?
History
Updated by saen acro almost 6 years ago
offtopic:
Why someone not request feature "Sat>IP device profiles".
This will solve problems with specific settings and protokol versions.
Updated by Ricardo Rocha almost 6 years ago
small apart Mister Pablo R. ... how does Kathrein EXIP 4124 perform? did you tried pids=all? does it support tcp/avm?
Updated by Pablo R. almost 6 years ago
Ricardo Rocha wrote:
small apart Mister Pablo R. ... how does Kathrein EXIP 4124 perform? did you tried pids=all? does it support tcp/avm?
It does not support pids=all or TCP mode. Only UDP.
Updated by Pablo R. about 5 years ago
Fixed on 6c6e0e5103b874fdd926b0f1bcdaed4d7e8b464e and fb06654aea29c13d883314c03573ddcf6a77c954. Thanks.