Hello,
I am using 2 cards, 1 S2-3200 and 1 HVR4000. I have 2 dishes, 1 aimed to astra 19 and the other to hotbird. both are connected with disecq switch on both cards.
with the S2-3200 everything is working perfect on both satellites.
With the HVR4000 I get continuity counter errors.
The errors are appearing +/- 1 minute after tuning to a channel. In the beginning I can't see any effect on the video. After another minute I see more and more errors in thelog and effects on the video and audio.
With VDR both cards are working perfectly.
Any idea how to solve this ?
I am on lucid + SVN R5322
many thanks
splinux
History
Updated by nilzen - about 14 years ago
Disable "idle scanning" on your S2-3200 card and the problems will go away.
Updated by Andreas Smas about 14 years ago
- Status changed from New to Fixed
- Found in version set to invalid
Hardware trouble